FAQs

Heating and Cooling Repair NJ

Heating and Cooling Repair NJ

Heating and Cooling Repair NJ

 

 

Q: Maria of Jackson  New Jersey “I am  getting  cold air  , coming out the vent  my   heating  furnace is not working what to do”?

Heating and Cooling Repair NJ

A:  You need to read your instruction manual and  find out how  to reset your furnace if it’s an oil  boiler with  bucket  burner  usually you can reset it by pushing the red button  on  gas furnace  you can turn the power  usually you have switch by the furnace or  by the stairs leading to the basement

If this does not help – the call Air Conditioning specialties  732-961-6544 to schedule a service call for your appliance.

See what our customer say about us

Rheem failure codes

dan jackson nj Question

I have a Rheum  furnace I’m getting error code slow blinking  what can be the problem

FLAME LED
The FLAME LED is an indication of the presence of flame.
OFF – No flame is detected.
Rapid Blink – Unexpected Flame
Slow Blink – Marginal Flame Sense
Steady ON – Normal Flame Detected
STATUS LED
The STATUS LED is an indication of a fault present.
Steady ON – Normal Fault detected.
1 Blink – Ignition failure – 1 HR lockout
2 Blinks – Pressure switch stuck open switch will not close when inducer is on.
3 Blinks – Limit switch open main limit or roll-out control.
4 Blinks – Pressure switch stuck closed. Switch will not open.
5 Blinks – Not applicable.
6 Blinks – Line and Neutral reversed.
POWER LED
The POWER LED is an indication of 24ac power to the board.
OFF – No power (24VAC) to control board.
ON – Control is powered.
CFM LED
The CFM LED is an indication of target airflow. This is a reasonably close approximation of the airflow pushed by the blower motor through the furnace.
Because of manufacturing and measurement tolerances, air density, humidity, ambient air temperature and other things, the CFM actually measured may vary significantly from this target value.
One Blink represents 100 CFM of target
airflow. A half blink represents approx. 50 CFM. When the blink sequence is complete, there will be a noticeable pause of approximately one second before the sequence repeats. For example, if eleven and one half blinks are counted followed by a one second pause and then eleven and one half blinks are counted again, the target airflow is approximtely 1150 CFM.

JOHN  New Jersey eating repair  answer

I highlight  the error  it’s look like the flame sensor is not functioning clean the flame sensor this result the furnace problem.

James heating problem in Jackson New Jersey

I have York furnace the flame is not starting what can be the problem

York furnace error codes
Fault condition Red lite
Power on On
Limit circuit open or external load on “W” 1 flash
Pressure switch is open with inducer on 2 flashes
Pressure switch is closed with inducer off 3 flashes
Ignition failure (check ground) 4 flashes
115 VAC & neutral reversed or no ground 5 flashes
False flame or gas valve relay shorted continuous
Power off off
Yellow
lite
Low flame senser signal continuous flash
Flame present on

the control board on your diamond furnace is in the bottom of the furnace look for the  clear glass  don’t open it look inside for the error code blinking flashes

david  freehold New Jersey

I have

wrote to you as a courtesy of

Heating and Cooling Repair NJ

Modine/UT Ignition Control Board Failure Codes

A Green LED labeled “OK” is provided to indicate system faults.
Steady OFF Steady ON Fast Flash 1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
Internal control fault or no power Normal operation, no call for heat Normal operation, call for heat present
Pressure switch does not close within 30 seconds of inducer energized.
Pre-Purge – The control energizes the induced draft motor and waits for the pressure switch to close. If the pressure switch does not close within 30 seconds of the inducer energizing, the control will flash “1” on the LED. The control will leave the inducer energized indefinitely as long as the call for heat remains and the pressure switch is open.
Pressure switch is closed before inducer is energized.
Call for Heat – The control checks to see if the pressure switch is open. If the pressure switch is closed, the control will flash “2” on the LED and wait indefinitely for the pressure switch to open.
Limit switch is open
Limit Operation – The limit switch is ignored unless a call for heat is present (W energized). If the limit switch is open and a call for heat is present, the control de-energizes the gas valve and runs the indoor blower motor on heat speed, and runs the induced draft motor. The control will flash “3” on the LED until the limit switch closes. When the switch re-closes or the call for heat is lost, the control runs the induced draft motor through post-purge and runs the indoor blower through the selected fan off delay. The control will return to normal operation after the blower off delay is completed.
In lockout from failed ignitions or flame losses
Ignition Retry – If flame is not established on the fifth trial for ignition (initial try + 4 re-tries), the control de-energizes the gas valve and goes into lockout. The control flashes a “4” on the LED to indicate ignition failure lockout.
Twin communications fault
A Twin Communications Fault will occur if the 24 VAC supply to the twins are not in phase with each other, or power is removed from one of the twins. While a Twin Fault exists, the control does not respond to thermostat commands and flashes “5” on the status LED. Open limit and undesired flame response are still operational. The control continually tries to establish communication and automatically resumes normal operation when communication is re-established. If a twin fault occurs during a heat cycle, both furnaces terminate the call for heat immediately. The only chance for blower mis-synchronization is if the blower off delays are set differently on the twins. If a twin fault occurs during high speed fan or continuous fan, both controls shut blowers off immediately.
Limit Switch tripped 5 times during heat cycle
Limit Operation – If the limit switch has 5 trips per call for heat, the control will go into a hard lockout and the LED will flash “6”. Lockout may be manually reset by removing power from the control for more than 1 second or removing the thermostat call for heat for more than 1 and less than 20 seconds
5 flames losses during one heat cycle.
Ignition Re-Cycle – The control will re-cycle up to 5 flame losses (4 re-cycles) within a single call for heat before going to lockout. The LED will flash “7” during this lockout.
A Yellow LED labeled “FLAME” is provided to indicate flame status
Flame Status – When flame is sensed, the flame LED is lit. If the flame current is below 1.0 uA (+/-50%), the flame LED will flash slowly to indicate “weak” flame. The Flame LED will flash fast if flame is present with gas valve off. If flame is sensed longer than 4 seconds while the gas valve is de-energized, the control shall energize the induced draft motor and indoor blower motor on heat speed. When flame is no longer sensed, the induced draft motor will run through post-purge and the indoor blower motor will run through the selected heat fan off delay time. The control will do a soft lockout, but will still respond to open limit and flame. The Flame LED shall flash rapidly when lockout is due to undesired flame.
Soft Lockout – The control shall not initiate a call for heat or call for continuous fan while in lockout. A call for cooling operates as normal. The control will still respond to an open limit and undesired flame. Lockout shall automatically reset after 1 hour. Lockout may be manually reset by removing power from the control for more than 1 second or removing the thermostat call for heat for more than 1 and less than 20 seconds.
Hard Lockout – If the control detects a fault on the control board, the status LED will be de-energized and the control will lockout as long as the fault remains. A hard lockout will automatically reset if the hardware fault clears.

Nordyne M1M, N1B series error codes 

Modine control board